Detailaufnahme S 7 OWAplan
Key
1 Nonius hanger lower part no. 2001, spacing ≤ 1000 mm
2 Supporting grid CD profile 60/27 no. 2003, spacing ≤ 1000 mm
3 Profile connector no. 2005
4 Cross connector no. 2004
5 Tile grid CD profile 60/27 no. 2003, spacing ≤ 400 mm
6 Wall angle no. 51/22 resp. no. 51/27
7 Tile screw no. 2019, spacing ≤ 300 mm resp. 400 mm
8 U-shaped hanger no. 2012 for inclined installation/direct mounting, to be
shortened on site, spacing ≤ 1000 mm
9 Self-tapping screw no. 2024
10 Plaster coating
11 Board width
12 Board length
13 OWAplan ceiling board

Source: DS 1021

Technical data

Dimensions

OWAplan70: 2400 x 1200 x 20 mm
OWAplan90: 2400 x 1200 x 25 mm

Edge

3

Tile thickness

OWAplan70: 20 mm
OWAplan90: 25 mm

Building material class

A2-s1,d0 in accordance with EN 13501-1
class 1 (ASTM E84) | class A (ASTM E1264)

Resistance to fire

Under reinforced concrete ceiling up to REI 60 (EN 13501-2)

Metal system

All metal parts galvanized. For further details see OWAplan assembly instructions

Minimum suspension depth

Suspension depth 180 mm (depending on the existing raw ceiling).
Direct fixing approx. 80 – 90 mm. from the raw ceiling

Contact

Need technical support?

We will be happy to assist you personally if you have any questions about this product.

Contact